Electrician and Wireman MCQ Quiz - Objective Question with Answer for Electrician and Wireman - Download Free PDF

Last updated on May 14, 2025

Latest Electrician and Wireman MCQ Objective Questions

Electrician and Wireman Question 1:

Which of the following is a fundamental principle for electrical installations, according to safety standards?

  1. Electrical circuits must be designed to operate without any protective devices
  2. Electrical installations must ensure protection against electric shock, overcurrent and fault currents
  3. Electrical systems should prioritise cost over safety considerations
  4. Electrical installations do not require grounding or earthing systems

Answer (Detailed Solution Below)

Option 2 : Electrical installations must ensure protection against electric shock, overcurrent and fault currents

Electrician and Wireman Question 1 Detailed Solution

The correct answer is option 2.

The fundamental principle for electrical installations aligns directly with international safety standards such as IEC 60364 and NFPA 70 (NEC), which emphasize:

  • Protection against electric shock
  • Overcurrent protection (including overloads and short circuits)
  • Protection against fault currents
  • Proper grounding and bonding


These are foundational principles to prevent injury, fire, and equipment damage. The other options contradict safety standards and could pose serious hazards if followed.

Electrician and Wireman Question 2:

Which of the following statements is INCORRECT referring to energy from bio mass?

  1. Bio mass has a high calorific value.
  2. Bio mass is solar energy stored in organic matter.
  3. Bio mass is a renewable energy source.
  4. The use of bio mass for energy causes no net increase in carbon dioxide emissions to the atmosphere.

Answer (Detailed Solution Below)

Option 1 : Bio mass has a high calorific value.

Electrician and Wireman Question 2 Detailed Solution

Biomass

  • Biomass is an environmentally-friendly, renewable energy source.
  • It is produced when organic matter, such as food or animal waste, is broken down by microorganisms in the absence of oxygen, in a process called anaerobic digestion.
  • In a biogas power plant, biomass is burned in a boiler to produce high-pressure steam. This steam flows over a series of turbine blades, causing them to rotate. The rotation of the turbine drives a generator, producing electricity.
  • Bio methane is the primary component of biogas, which is produced from the anaerobic digestion of animal waste, organic waste, and agricultural residues.
  • Biomass mainly consists of methane (CH4) (50-75%), carbon dioxide (CO2) (25-50%), and traces of other gases.
  • Some of the most popular biomass choices are crop residues, municipal and industrial sewage, agricultural material, livestock manures, seaweed, food-processing, and paper wastes.


Explanation
 

  • Biomass does not have a high calorific value compared to fossil fuels like coal or petroleum. While it provides energy, its calorific value is lower than conventional fossil fuels.
  • The other statements are scientifically valid, as biomass stores solar energy, is renewable, and carbon-neutral in the long term (although combustion releases CO₂, plants absorb CO₂ during their lifecycle).


Hence, option 1 is the correct answer.

Electrician and Wireman Question 3:

In the case of the outdoor type of sub-station, metallic fencing of NOT less than _________ m height shall be erected around the transformer.

  1. 1.8
  2. 3
  3. 1.5
  4. 1

Answer (Detailed Solution Below)

Option 1 : 1.8

Electrician and Wireman Question 3 Detailed Solution

Fencing Requirements for Outdoor Substations

  • The minimum height of metallic fencing around a transformer in an outdoor substation should be 1.8 meters.
  • In high-security areas, the height may be increased to 2.4 meters (8 feet) or more with barbed wire on top.
  • Three strands of barbed wire should be installed at a 45-degree outward angle on top of the fence.
  • The IEEE Std. 80-2013 recommends grounding every 15-30 meters (50-100 feet) along the fence.

 

Difference between Indoor and Outdoor Substations:

Parameters Indoor Substation Outdoor Substation
Construction The construction of the indoor substation is complicated. The construction of the outdoor substation is not more complicated.
Voltage These substations are installed up to the 66kV voltage level. These substations are installed beyond the 66kV voltage level.
Location Generally, the indoor substations placed inside the building. The outdoor substations are placed outside the building.
Space Required There is required a small space. There is required plenty of space.
Installation Cannot easily expand the installation of indoor substations. Can easily expand the installation of outdoor substations.
Cost The cost of the indoor substation is low. The cost of the outdoor substation is high.
Fault Condition Very easy to clear the fault. Very difficult to clear the fault.
Maintenance Indoor substation requires high maintenance.  Outdoor substation requires less maintenance. 
Safety Indoor substations are much safer. Outdoor substations are not much safer.

 

Electrician and Wireman Question 4:

Identify the device symbol.

qImage67c97f1331a7004b44af15bc

  1. GTO
  2. BJT
  3. MOSFET
  4. IGBT

Answer (Detailed Solution Below)

Option 4 : IGBT

Electrician and Wireman Question 4 Detailed Solution

The symbols of various power electronics devices are:

IGBT (Insulated Gate Bipolar Transistor)

qImage67d58bf979a11b7b9ae6d12e

MOSFET (Metal Oxide Semiconductor Field Effect Transistor)
qImage67d58bfa79a11b7b9ae6d131

GTO (Gate Turn-Off Thyristor)

qImage67d58bfa79a11b7b9ae6d132

BJT (Bipolar Junction Transistor)

qImage67d58bfb79a11b7b9ae6d133

Electrician and Wireman Question 5:

Which statement below is NOT true about Corona?

  1. The rough and irregular surface of the conductor will give rise to more Corona.
  2. In stormy weather, corona occurs at a much higher voltage compared to fair weather. 
  3. Lesser spacing between the conductors will give rise to more Corona.
  4. Lower the line voltage corona effect will be lower.

Answer (Detailed Solution Below)

Option 2 : In stormy weather, corona occurs at a much higher voltage compared to fair weather. 

Electrician and Wireman Question 5 Detailed Solution

Corona Effect in Transmission Lines

Corona discharge is a phenomenon in high-voltage transmission lines where ionization of air occurs around conductors, leading to a bluish glow, hissing noise, power loss, and sometimes ozone formation. It happens when the electric field intensity around the conductor exceeds the dielectric strength of air (~30 kV/cm).

The corona loss depends upon:

  • Frequency of supply: Corona loss increases as the supply frequency increases.
  • Air Pressure: In hilly areas, the corona effect is more dominant due to reduced pressure.
  • By increasing conductor size, the voltage at which corona occurs is raised and hence corona effects are considerably reduced.
  • By increasing the spacing between conductors, the voltage at which the corona occurs is raised and hence corona effects can be eliminated.


Statement 2 is NOT true about corona.  The correct statement is: In stormy weather (high humidity, rain, etc.), corona occurs at a lower voltage because moisture increases air conductivity, reducing the breakdown voltage.

Hence, option 2 is the correct answer.

Top Electrician and Wireman MCQ Objective Questions

What happens when an alternator is said to be over excited?

  1. Negative power factor
  2. Unity power factor
  3. Lagging power factor
  4. Leading power factor

Answer (Detailed Solution Below)

Option 3 : Lagging power factor

Electrician and Wireman Question 6 Detailed Solution

Download Solution PDF

An overexcited alternator always supplies lagging current to the connected load, which means that load is of lagging nature. Lagging load take active and reactive power from the supply or alternator. Therefore, reactive power flows outwards from an over-excited alternator.

Important Points:

  • Under excited alternator works at the leading power factor
  • The normal excited alternator works at the unity power factor
  • The overexcited alternator works at lagging power factor

Mistake PointsFor Synchronous motor its opposite of alternator,

  • Under excited synchronous motor works at lagging power factor
  • The normal excited synchronous motor works at the unity power factor
  • The overexcited synchronous motor works at a leading power factor

The speed of a squirrel cage motor ________

  1. is changed by changing the number of stator poles
  2. varies as per the stator line current
  3. incorporates the resistance of rotor circuit
  4. is changed by changing the rotor pole

Answer (Detailed Solution Below)

Option 1 : is changed by changing the number of stator poles

Electrician and Wireman Question 8 Detailed Solution

Download Solution PDF

The speed of the induction motor can be controlled by the following methods:

1) V/f control (or) frequency control

2) Changing the number of stator poles

3) Controlling supply voltage

4) Changing winding resistance by adding rheostat in the stator circuit

We can apply all these methods to slip ring induction motors, but the adding resistance in the stator circuit is not possible for squirrel cage motors as rotor bars are short-circuited using end rings.

The symbol in the given figure shows a:

1 U.B Deepak 20.03.2020 D 2

  1. Servo motor
  2. 3-phase induction motor
  3. Synchronous motor
  4. DC motor

Answer (Detailed Solution Below)

Option 4 : DC motor

Electrician and Wireman Question 9 Detailed Solution

Download Solution PDF

Given figure shows the symbol of DC shunt motor

F1 J.P Deepak 20.02.2020-D1

The permissible temperature rise of electrical machines is determined by the type of _____.

  1. material used for winding wire
  2. funni used for winding
  3. insulation materials used for winding 
  4. varnish used

Answer (Detailed Solution Below)

Option 3 : insulation materials used for winding 

Electrician and Wireman Question 10 Detailed Solution

Download Solution PDF

Temperature rises in electrical Machines are due to power losses occurring in various parts of the machines.

The various power losses occurring are rotational loss, friction and windage loss, and electrical and magnetic losses.

The permissible temperature rise of electrical machines is determined by the type of insulation materials used for winding.

Properties of insulating materials for electrical machine

A perfect insulating material ought to possess the subsequent properties:

  • High dielectric strength.
  • It should withstand high temperatures.
  • Good thermal conductivity.
  • It should not undergo thermal oxidation.
  • It should withstand vibration, abrasion, and bending.
  • Not to absorb moisture.

A heater operates at 220 V and has 99 percent efficiency. Its energy consumption is 1.5 kWhr. What will be the input current of the heater?

  1. 22 A
  2. 6.82 A
  3. 2.22 A
  4. 7.56 A

Answer (Detailed Solution Below)

Option 2 : 6.82 A

Electrician and Wireman Question 11 Detailed Solution

Download Solution PDF

Concept:

The energy is given by:

\(E=P\times t\)

\(E=(V\times I)\times t\)

where, I = Current

R = Resistance

t = Time

Calculation:

Given, V = 220 V

E = 1.5 kW

t = 1 hr

\(1.5\times 10^3=220\times I\times 1\)

I = 6.82 A

What is represented by the below symbol?

RRB ALP CBT2 22nd Jan Shift 2 uday D2

  1. Battery
  2. Capacitor
  3. capacitor polarized
  4. Resistor

Answer (Detailed Solution Below)

Option 3 : capacitor polarized

Electrician and Wireman Question 12 Detailed Solution

Download Solution PDF

Identify the type of joint shown in the picture from the given options.

F2 U.B Madhu 30.01.20 D1

  1. Scarfed Joint
  2. Tee Joint
  3. Britannia Joint
  4. Rat Tail Joint

Answer (Detailed Solution Below)

Option 4 : Rat Tail Joint

Electrician and Wireman Question 13 Detailed Solution

Download Solution PDF

Pig Tail:

This joint is also called as Pig-tail/Rat-tail/Twisted joint.

This joint is suitable for pieces where there is no mechanical stress on the conductors, as found in the junction box or conduit accessories box

RRB JE EC  79 11 Q magnetic materials and  Jointing of wires Hindi images madhu and shashi Q9

Married joint:

A married joint is used in places where appreciable electrical conductivity is required, along with compactness.

As the mechanical strength is less, this joint could be used at places where the tensile stress is not too great.

RRB JE EC  79 11 Q magnetic materials and  Jointing of wires Hindi images madhu and shashi Q9a

Britannia joint:

This joint is used in overhead lines where considerable tensile strength is required. It is also used both for inside and outside wiring where single conductors of diameter 4 mm or more are used.

RRB JE EC 79 11 Q magnetic materials and Jointing wires Hindi images madhu and shashi Q10b

What is the name of tool shown in figure?

F1 U.B Madhu 30.01.20 D5

  1. Bent snip
  2. Side cutting plier
  3. Hand crimping plier
  4. Straight snip

Answer (Detailed Solution Below)

Option 3 : Hand crimping plier

Electrician and Wireman Question 14 Detailed Solution

Download Solution PDF

The nominal voltage for lead-acid cells is:

  1. 24 V
  2. 2 V
  3. 1.4 V
  4. 12 V

Answer (Detailed Solution Below)

Option 2 : 2 V

Electrician and Wireman Question 15 Detailed Solution

Download Solution PDF

 

Type

Voltage (in V)

Primary cell

Carbon zinc

1.5

Zinc-chloride

1.5

Manganese alkaline

1.5

Silver oxide

1.5

Lithium

2.95

Mercury

1.35

Secondary cell

Lead-acid

2.2

Nickel-iron(Edison cell)

1.36

Nickel-cadmium

1.25

Silver zinc

1.86

Silver cadmium

1.1

Get Free Access Now
Hot Links: teen patti master golden india teen patti 500 bonus teen patti gold new version 2024 teen patti apk download teen patti rules