Question
Download Solution PDFAnti-siphonage pipe is connected to:
This question was previously asked in
OSSC JE Civil Mains (Re-Exam) Official Paper: (Held On: 3rd Sept 2023)
Answer (Detailed Solution Below)
Option 3 : Top of P-Trap of W.C.
Free Tests
View all Free tests >
OSSC JE Civil Geo-technical Engineering Mock Test
0.7 K Users
20 Questions
40 Marks
36 Mins
Detailed Solution
Download Solution PDFExplanation:
Anti siphonage pipe:
- An extra pipe connected to the outlets of toilet seats of all the floors, the other end of which is exposed to atmosphere is called anti-siphonage pipe.
- These are provided to maintain water seal so that foul gases of the sewer line do not find entry in to the toilet/ bathrooms.
- It is connected at the top of the P-Trap because this location helps maintain air pressure balance and prevents the water seal from being sucked out when wastewater flows through the main soil pipe.