In a 3-phase induction motor, the maximum torque under standstill occurs when the rotor resistance (R2) is:

This question was previously asked in
MPPGCL JE Electrical 19 March 2019 Shift 2 Official Paper
View all MPPGCL Junior Engineer Papers >
  1. equal to leakage reactance (X1 + X2)
  2. greater than leakage reactance (X1 + X2)
  3. less than leakage reactance (X1 + X2)
  4. almost equal to X1 - X2

Answer (Detailed Solution Below)

Option 1 : equal to leakage reactance (X1 + X2)
Free
MPPGCL JE Electrical Full Test 1
100 Qs. 100 Marks 120 Mins

Detailed Solution

Download Solution PDF

Torque in the 3-phase induction motor

The torque of a 3-phase induction motor is given by:

where, V = Supply

ωs = Synchronous speed in radian/sec

R2 = Rotor resistance

X2 = Rotor reactance

s = Slip

Condition for maximum torque

The maximum torque of a 3-phase induction motor occurs at:

If the maximum torque has to occur in starting, the value of the slip (s)=1

The maximum torque of a 3ϕ induction motor occurs when rotor resistance is equal to leakage reactance (X1 + X2).

Latest MPPGCL Junior Engineer Updates

Last updated on May 29, 2025

-> MPPGCL Junior Engineer result PDF has been released at the offiical website.

-> The MPPGCL Junior Engineer Exam Date has been announced.

-> The MPPGCL Junior Engineer Notification was released for 284 vacancies.

-> Candidates can apply online from 23rd December 2024 to 24th January 2025.

-> The selection process includes a Computer Based Test and Document Verification.

-> Candidates can check the MPPGCL JE Previous Year Papers which helps to understand the difficulty level of the exam.

Hot Links: dhani teen patti teen patti 3a teen patti online game teen patti rummy